I would like to pass on the problem I have encountered inconnection with the QRO modification to the Kenwood TS830S, TS-530S and the TS-530SP. The problem occurs after many hours of long winded QSO's. It seems that with the increase in the screen voltage from 210 to 300 volts, R37 on the RF unit (#X44-1360-00) heats up tremendously and will change it's value so greatly that even the receive either suffers or goes out totally. R37 originally is Metalfilm resistor at 3.3K ohms and is 1/2 watt. I have changed mine to a Metalfilm as original same value but have used a one watt resistor. The brand I was able to get was RCA and I suppose there are better on the market. This is a 2% tolerance. Three units that I know of have had this problem that I took care of in this area alone. Two units were TS-830S and one a TS-530SP. Just thought I would pass that information along for what it is worth. (Thanks, FrankJ. Lukas, Jr., 5301 Main Ave., North Ridgeville, OH 44039)